Taylors Doors

Home Page

Taylors Joining System

Standard Door Frame Components

frame

Standard Profiles

Fire Door Frames

Sliders and Series 2000

Backfill Requirements

Fire rated doors

Profile Measurements

Orders

Pricing

20 Orchard Rd
Brookvale
NSW 2100
Tel: 02 9905 1222
Fax: 02 9905 2885

Email: taylorsdoors@tpg.com.au

 

Backfill Requirements

Wall Type Doorset Type Maximum Door Leaf Size in mm Frame Thickness in mm Backfill Required New Standards 1905.1 2005 Fire Resistance Levels up to
Masonry
Built in or Retrofit
MINI
Single Leaf
2350 x 1200
1.1
YES
NA/120/30
MAXI
Single Leaf
2400 x 1200
1.4
YES
NA/120/30

Masonry
(Built in only)

MAXI
Single Leaf
3500 x 1200
3000 x 1500
1.4
YES
NA/240/30
Masonry
Built in or Retrofit
MAXI
Double Leaf
2400 x 2400
1.4
YES
NA/120/30
Masonry
(Built in only)
MAXI
Double Leaf
3500 x 2400
3000 x 3000
1.4
YES
NA/240/30
Plasterboard
MINI
Single Leaf
2350 x 1200
1.1
YES
NA/120/30
MAXI
Single Leaf
2400 x 1200
1.4
YES
NA/120/30
MAXI
Single Leaf
3000 x 1500
1.4
YES
NA/180/30
MAXI
Double Leaf
2400 x 2400
1.4
YES
NA/120/30
MAXI
Double Leaf
3000 x 3000
1.4
YES
NA/180/30
Hebel Wall
MINI
Single Leaf
2350 x 1200
1.4
YES
NA/120/30
MAXI
Single Leaf
2400 x 1200
1.4
YES
NA/120/30
MAXI
Double Leaf
2400 x 2400
1.4
YES
NA/120/30
Rapidwall Wall Systems
MINI
Single Leaf
2350 x 1200
1.4
YES
NA/120/30
MAXI
Single Leaf
2400 x 1200
1.4
YES
NA/120/30
MAXI
Double Leaf
2400 x 2400
1.4
YES
NA/120/30

Notes:
1. The door frame rebate width is 41mm for mini fire doors and 51mm for maxi fire doors.
2. The minimum depth of the door stop for all fire doors is 25mm.